VISION I


CLIK FOR ENLARGE
 
The idea for this device came because of my knowledge of acupuncture that I got from my parents,
who are in for it for a long time, and especially my mother to whom acupuncture is a profession.
It has been used actively for several years now.
This is an electronic device which multiplies the effect of acupuncture therapy.
The unique characteristic of the device is that it does not disturb the strict traditional rules of acupuncture therapy, and still multiplies the effect.
That kind of effect achieves fantastic results because even an inexperienced acupuncturist can acquire the necessary experience faster.
Practice has shown that the moment of the puncturing is the positive shock for the organism, and also the moment of the most active stimulation of the acupuncture spot.
In time, the spot of the puncture adapts to the needle. The need for oscillating of the needle to achieve more efficient results has been known for more than two thousand years, and represents the most reliable method of treatment by acupuncture. The essence of the mechanical stimulation is to not let the acupuncture spot adapt to the influence of the needle. The mechanical vibrations have been performed by scratching the handle of the acupuncture needle with a fingernail. Vision I is to use the electromechanical impulses to transmit micro-vibrations of certain sequence of frequencies to the acupuncture needle which then transmits them to the very acupuncture spot.
The frequencies are chosen in such a manner that the adaptation can not occur, and the stimulation continues for whole 15 minutes.
By this, the primary efficiency of the acupuncturist is significantly increased. The second effect is the acupuncturist’s quicker comprehension of the secrets of acupuncture and achievement of excellent results. Two modes are available: the automatic and the manual mode.
The automatic mode enables the device to choose the necessary frequencies until the end of the treatment. The sequence of frequencies in this mode is the following:
1Hz, 2Hz, 4Hz, 8Hz, 16Hz, 32Hz, 64Hz, 128Hz, 256Hz, and 512Hz.
The duration of the stimulation for every frequency is 1m 30sec, or 15 minutes per treatment, after which the device automatically shuts down and signalizes the end of the treatment.
It is exactly because of this sequence of frequencies that the adaptation of the acupuncture spot can not occur. The duration of the stimulation is chosen in such a manner that the frequency changes, always being twice the value of the previous one, before the spot reaches the adaptation (1m, 30sec).
Manuel stimulation can not reach even a close stability of the frequency and the amplitude.
With this device comes either the red or the infrared laser. The power of the infrared laser is 10mW, and the wavelength either 820nm or 904nm, whereas the power of the red laser is also 10mW, but with the wavelength of 670nm.
The aim of the therapy is to stimulate certain functions, either directly, or reflexively, but without any harmful side effects. The usage of the lasers of small power is for bio-stimulation of cells, analgesic (pain killing) and anti-inflammatory effects.